← Volver atrás
Publicaciones

LISA Pathfinder Performance Confirmed in an Open-Loop Configuration: Results from the Free-Fall Actuation Mode

Autores

Armano, M. , Audley, H. , Baird, J. , Binetruy, P. , Born, M. , Bortoluzzi, D. , Castelli, E. , Cavalleri, A. , Cesarini, A. , Cruise, A. M. , Danzmann, K. , Silva, M. de Deus , Diepholz, I. , Dixon, G. , Dolesi, R. , Ferraioli, L. , Ferroni, V. , Fitzsimons, E. D. , Freschi, M. , Gesa, L. , Gibert, F. , Giardini, D. , Giusteri, R. , Grimani, C. , Grzymisch, J. , Harrison, I. , Hartig, M-S. , Heinzel, G. , Hewitson, M. , Hollington, D. , Hoyland, D. , Hueller, M. , Inchauspe, H. , Jennrich, O. , Jetzer, P. , Karnesis, N. , Kaune, B. , Korsakova, N. , Killow, C. J. , Lobo, J. A. , Liu, L. , Lopez-Zaragoza, J. P. , Maarschalkerweerd, R. , Mance, D. , Meshksar, N. , Martin, V. , Martin-Polo, L. , Martino, J. , Martin-Porqueras, F. , Mateos, I. , McNamara, P. W. , Mendes, J. , Mendes, L. , Nofrarias, M. , Paczkowski, S. , Perreur-Lloyd, M. , Petiteau, A. , Pivato, P. , Plagnol, E. , Ramos-Castro, J. , Reiche, J. , Robertson, D. I. , RIVAS GARCÍA, FRANCISCO, Russano, G. , Slutsky, J. , Sopuerta, C. F. , Sumner, T. , Texier, D. , Thorpe, J. I. , Vetrugno, D. , Vitale, S. , Wanner, G. , Ward, H. , Wass, P. J. , Weber, W. J. , Wissel, L. , Wittchen, A. , Zweifel, P.

Publicación externa

Si

Medio

Phys Rev Lett

Alcance

Article

Naturaleza

Científica

Cuartil JCR

Cuartil SJR

Impacto JCR

8.385

Impacto SJR

3.588

Fecha de publicacion

11/09/2019

ISI

000485202800003

Abstract

We report on the results of the LISA Pathfinder (LPF) free-fall mode experiment, in which the control force needed to compensate the quasistatic differential force acting on two test masses is applied intermittently as a series of "impulse" forces lasting a few seconds and separated by roughly 350 s periods of true free fall. This represents an alternative to the normal LPF mode of operation in which this balancing force is applied continuously, with the advantage that the acceleration noise during free fall is measured in the absence of the actuation force, thus eliminating associated noise and force calibration errors. The differential acceleration noise measurement presented here with the free-fall mode agrees with noise measured with the continuous actuation scheme, representing an important and independent confirmation of the LPF result. An additional measurement with larger actuation forces also shows that the technique can be used to eliminate actuation noise when this is a dominant factor.

Miembros de la Universidad Loyola