Authors

Born, Michael , Armano, M. , Audley, H. , Auger, G. , Baird, J. , Bassan, M. , Binetruy, P. , Born, M. , Bortoluzzi, D. , Brandt, N. , Caleno, M. , Cavalleri, A. , Cesarini, A. , Cruise, M. , Danzmann, K. , de Deus Silva, M. , De Rosa, R. , Di Fiore, L. , Diepholz, I. , Dolesi, R. , Dunbar, N. , Ferraioli, L. , Ferroni, V. , Fitzsimons, E. , Flatscher, R. , Freschi, M. , Marrirodriga, C. Garcia , Gerndt, R. , Gesa, L. , Gibert, F. , Giardini, D. , Giusteri, R. , Grado, A. , Grimani, C. , Grzymisch, J. , Harrison, I. , Heinzel, G. , Hewitson, M. , Hollington, D. , Hoyland, D. , Hueller, M. , Inchauspe, H. , Jennrich, O. , Jetzer, P. , Johlander, B. , Karnesis, N. , Kaune, B. , Korsakova, N. , Killow, C. , Lobo, A. , Lloro, I. , Liu, L. , Lopez-Zaragoza, J. P. , Maarschalkerweerd, R. , Mance, D. , Martin, V. , Martin-Polo, L. , Martino, J. , Martin-Porqueras, F. , Madden, S. , Mateos, I. , McNamara, P. W. , Mendes, J. , Mendel, L. , Nofrarias, M. , Paczkowski, S. , Perreur-Lloyd, M. , Petiteau, A. , Pivato, P. , Plagnol, E. , Prat, P. , Ragnit, U. , Ramos-Castro, J. , Reiche, J. , Robertson, D. I. , Rozemeijer, H. , RIVAS GARCÍA, FRANCISCO, Russano, G. , Sarra, P. , Schleicher, A. , Shaul, D. , Slutsky, J. , Sopuerta, C. F. , Stanga, R. , Sumner, T. , Texier, D. , Thorpe, J. I. , Trenke, C. , Troebs, M. , Vetrugno, D. , Vitale, S. , Wanner, G. , Ward, H. , Wass, P. , Wealthy, D. , Weber, W. J. , Wissel, L. , Wittchen, A. , Zambotti, A. , Zanoni, C. , Ziegler, T. , Zweifel, P. , LPF Collaboration

External publication

Si

Means

J. Phys. Conf. Ser.

Scope

Proceedings Paper

Nature

Científica

JCR Quartile

SJR Quartile

SJR Impact

0.241

Publication date

01/01/2017

ISI

000437968700036

Abstract

The optical metrology system (OMS) of the LISA Pathfinder mission is measuring the distance between two free-floating test masses with unprecedented precision. One of the four OMS heterodyne interferometers reads out the phase difference between the reference and the measurement laser beam. This phase from the reference interferometer is common to all other longitudinal interferometer read outs and therefore subtracted. In addition, the phase is fed back via the digital optical pathlength difference (OPD) control loop to keep it close to zero. Here, we analyse the loop parameters and compare them to on-ground measurement results.